ADR-0048: Put progress on the control socket — last_successful_call_at and supervised children on list/describe

Proposed. This decision arrives as a design record alongside its implementation, because no maintainer decision on it exists yet: where the timestamp comes from, how children are read without putting a shell-out on a request path, and what the JSON shape is — those are what need reviewing. Nothing here is settled until this file reads status: accepted.

Context and Problem Statement​

Issue #958: an operator polling the control socket cannot see that an agent is wedged. harness_last_successful_call_timestamp already exists on /metrics (📝 ADR-0020), and 📝 ADR-0045 built a watchdog on that same signal, but the JSON snapshot answers with state: running and a screen idle_ms. A persistent crush harness blocked about 23 hours on a hung child — a recursive grep stalled on I/O — while its own process burned steady CPU and list reported it healthy. Anyone without a Prometheus scrape had to run ps by hand to find the child.

The gap is not that the daemon lacks the signal. It has three of them: the observer's tool-call feed (what the gauge and the watchdog read), the screen's silence (SPEC-0002's idle_ms, 📝 ADR-0040), and the process table. The gap is that only one of them reaches the surfaces most operators use, and none of them names what the process is waiting on.

Decision Drivers​

  • One value, one meaning. state describes the process. The new field must describe progress, and it must be the same progress /metrics exports, or two surfaces disagree about one harness and both are believed sometimes.
  • Nothing on the request path that did not need to be there. list is what the TUI refresh loop calls, several times a second at worst; a shell-out or a /proc walk inside a projection is a cost every client pays for a field most never read (the same reason 📝 ADR-0045 keeps process reads off the supervisor).
  • Unknown must not look like zero. 📝 ADR-0020 omits the gauge until the first success precisely because 0 renders as 1970 and puts 56 years of staleness on every panel; an empty children list must not read as "this agent has no children" when it means "the daemon could not look".
  • Nothing new leaves the machine, and nothing new is read. A child's arguments can carry whatever the agent passed to it, including credentials; the daemon must not put them on a socket everyone on the host can connect to.

Considered Options​

1. Where the timestamp comes from​

  • Option 1 — The metrics registry. internal/metrics keeps series.lastSuccess; give it an accessor and have the control plane call it. Rejected: the registry only exists when metrics_listen is on, so an operator who never enabled /metrics — exactly the audience for the control socket — would get a field that is silently always absent, and the control plane would depend on the scrape path.
  • Option 2 — The stall watchdog's progress clock. 📝 ADR-0045's guard already derives, per harness, the latest KindTool event — the same rule, from the same feed, that produces the gauge — and it runs whenever the daemon does. Chosen: one LastCall(name) accessor and the field appears, with no second derivation of "progress" anywhere in the tree.
  • Option 3 — Derive it again in the daemon package. Rejected: a third copy of the rule is how two surfaces end up disagreeing, which is driver one.

2. How children are read​

  • Option 1 — ps per list/describe. Rejected: that is a shell-out on the refresh path, and 📝 ADR-0045 says out loud it does not belong there.
  • Option 2 — The server samples the process table on a timer; the projection reads the last sample. Chosen. One ps every 15 seconds, whatever the client count, and the projection cost is a mutex and a slice.
  • Option 3 — Walk /proc or use a libproc binding. Rejected: the tree reads the process table through ps(1) already (📝 ADR-0045), which works on Linux, macOS and the BSDs with no privileged access; a second mechanism would be one more thing to get right per platform for no additional truth.

3. What a child is on the wire​

  • Option 1 — Executable name only. Chosen: pid, command, started_at, cpu_ms. comm is what names a hung grep; argv is what carries a token.
  • Option 2 — Full argv. Rejected on the last driver above; a wider field that leaks is not worth the one extra clue it adds, and the kernel truncates comm to 15 characters anyway, which is enough to spot the stuck tool.

Decision Outcome​

HarnessInfo gains two additive fields (ProtoMinor 28), and describe prints them as rows.

Progress is the same instant the gauge carries​

last_successful_call_at (RFC 3339) is stallguard.Guard.LastCall(name) — the latest observed tool call — formatted by the daemon's control plane. It is reported whether or not the harness is running and whether or not it configured a stall_timeout: it is the harness's history in this daemon's lifetime, not its process's. Omitted when nothing has been observed, which is a finding in itself for a harness list calls running, and is phrased as none since the daemon started rather than a date.

Children come from a sample, not from the request​

The server owns a procSampler reading the whole process table on a 15-second interval (ps -e -o pid=,ppid=,etime=,time=,comm=) and the projection reads what the last pass found. Consequences accepted with the choice:

  • A child that starts and exits inside one interval is never named. This answers "what has been sitting there for hours", which is the question #958 asks; the alternative is a ps for every list the TUI draws.
  • The sample is up to one interval stale, so a freshly spawned child may not appear on the first describe after it starts.
  • started_at comes from the table's elapsed column, so it is accurate to the second and derived as now − elapsed — lstart was not used because its format is the least portable thing ps prints.
  • cpu_ms is cumulative user+system time. Age plus near-zero CPU is the whole wedged-child reading; the daemon computes no delta, because two samples in a read-only snapshot would be a second clock to keep.

Only a harness whose state is running gets children: the snapshot's pid is the last one the harness had, and a stopped harness's pid may already belong to another process, whose tree would then be reported as the harness's.

Unknown is absent, never empty​

last_successful_call_at is omitted until the first observed call, and children is omitted when the harness is not running or the sampler has never succeeded (a container with no procps). Neither is ever an empty list or a zero. Where ps is missing the sampler logs one debug line and stops trying to be interesting; the fields simply stay off.

Listing children is capped at the eldest 24​

proctree.ChildLimit is 24, ordered eldest first. A worker that fanned out a hundred children still names the one that hung first, which is the one the operator is asking about.

The CLI prints rows, not new columns​

describe gains last call (relative age and the absolute time) and one child row per child (pid … · command · up … · cpu …). list's table is unchanged: the state column already carries the glyphs it carries, and a list is a summary — describe and --json are where the detail lives.

Consequences​

Positive

  • A wedge is visible from the one surface an operator already polls, with no Prometheus required.
  • The ps a human would have run is now something the daemon runs once per interval for every client at once.
  • Progress has one definition in the tree, so the gauge, the watchdog and the socket cannot drift into three meanings of "is it working".

Negative

  • One more goroutine per daemon, and a ps every 15 seconds whether or not anyone reads it. Deliberate, and cheap next to the observer's poll loop.
  • The child list is up to one interval stale, and short-lived children are invisible. An operator who needs the exact instant a child appeared is reading the harness's own log, not this field.
  • comm is truncated by the kernel on Linux, so two same-named children are distinguished only by pid and age.

More Information​

  • Issue #958 is the report; 📝 ADR-0045 is the write side of the same signal and explicitly left this read side to another record.
  • harness_session_active (📝 ADR-0020) answers a different question — whether the agent wrote to a session inside the idle window — and is not surfaced here, because the report is about a call that never returns, which is exactly when a session can look live.
  • A follow-up worth having: expose the watchdog's stall verdict and consecutive-stall count on the same surface, so "the guard found this stalled twice and gave up" reads without the log. 📝 ADR-0045 lists it as a follow-up too.
  • Making the interval a config key was considered and refused: nothing in the tree makes a sampling period operator-tunable, and a knob that can be set to an hour is a way to switch the field off without saying so.

Direct relationships declared in YAML frontmatter (per the SDD plugin's artifact-graph convention). Run /sdd:graph chain ADR-0048 for the transitive view.